Catalog Listings | AWM92100V | AWM92200V |
Flow Range (Full Scale) | +/- 200 sccm | |
Pressure Range | | +/- 2.0 H2O (5 mBar) |
Null Voltage Shift, Typ. | | |
-25°C to 25°C [-13ºF to 77ºF] | +/- 2.0 mV (1) | +/- 2.0 mV (1) |
25°C to 85°C [77ºF to 185ºF] | +/- 2.0 mV (1) | +/- 2.0 mV (1) |
Output Voltage Shift, Typ. | | |
-25°C to 25°C [-13ºF to 77ºF] | -3.0% FSO (2) | 25% Reading |
25°C to 85°C [77ºF to 185ºF] | +/-1% FSO (2) | -30% Reading |
1. Assumes low TCR Bridge resistance used (pins 2 and 8) |
2. Requires recommended RC value of 1K Ohm is used (pins 3 to 7) and typ. Heater control circuit. Maximum current RH. |
|
Specifications | Min. | Typ. Max. |
Excitation (1) | 8.0 Vdc | 10 ±0.01 Vdc 15.0Vdc |
Power Consumption | | 50 mW |
Calibration Gas | Air | |
Ratiometricity Error (1) | ± 0.30 typ. % Reading | |
Repeatability and Hysteresis (2) | ± 0.35% Reading | |
Response Time | 1 ms typ. | |
Pressure Drop @ Full Scale (200 sccm) | 0.49 typ. mBar | |
Overpressure | 25 psi max. | |
Operating Temperature Range | -25°C to 85°C[-13°F to 185°F] | |
Storage Temperature Range | -40°C to 90°C[-40°F to 194°F] | |
Vibration | 20g’s, 10Hz to 2000Hz | |
Shock | 100 g, 6 ms | |
Weight | 5.6 grams | |
1. Output voltage is ratiometric to supply voltage. |
2. Repeatability and Hysteresis tolerances reflect inherent inaccuracies of the measurement equipment. |