珠海科迈尔仪器仪表有限公司
暂无信息 |
simpson228 AC/DC泄漏电流测试表Simpson228根据新的UL,IEC标准设计,满足新的UL、IEC和ANSI规范。Simpson228兼容交流和直流的泄漏电流测量。模拟了人体的三种阻抗。Simpson228具有触电网络,摆脱网络,Unweighted Burn Hazard 网络三种测试模式。Simpson228仪器标配:鳄鱼夹,操作手册,测试表笔(可选配泄漏电流测试盒228-I型)
simpson228 AC/DC泄漏电流测试表
Simpson228根据新的UL,IEC标准设计,满足新的UL、IEC和ANSI规范。
Simpson228兼容交流和直流的泄漏电流测量。模拟了人体的三种阻抗。
Simpson228具有:触电网络,摆脱网络,Unweighted Burn Hazard 网络三种测试模式。
Simpson228仪器标配:鳄鱼夹,操作手册,测试表笔(可选配泄漏电流测试盒228-I型)
Opecifications
GENERAL
| Reaction ResponseNetwork | Let-Go ResponseNetwork | UnweightedBurnHazard Response Network | |
Equivalent network component values: | Complies with values specified in IEC 990 (excluding fuse) | |||
Equivalent measuring instrument load: | 1 MΩ- 10pF | 1 MΩ- 62 pF | 1 MΩ- 1 pF | |
Ranges: | 0.3, 1, 3, 10 M.I.U. | 0.3, 1, 3, 10 M.I.U. | 0-100 mA RMS | |
Current accuracy: | ±2% F.S. @ 60 Hz | |||
Meter measurement method: | True RMS | |||
Meter frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||
DC to 1 Hz | Pointer shall track within 5% of peak | |||
2Hz to 19Hz (Accuracy not supported) |
| |||
20 Hz to 200 KHz | ±2% F.S. | ±2.5% of F.S. | ±2% F.S. | |
200 KHz to 1 MHz | ±2% F.S. | ±2.5% F.S. | ±5% F.S. | |
Output sensitivity: | Full scale meter indication equals 1V RMS (Measured with a 1 MΩ- 12 pF load) | |||
Output accuracy: | ±2% of reading @ 60 Hz | |||
Output frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||
DC to 50Hz | ±2% of reading | |||
50 Hz to 100 KHz | ±2.5% of reading | ±2% /-3% of reading | ±2% of reading | |
100 kHz to 1 MHz | ±5% of reading | |||
Voltmeter range: | 0-300 V (AC or DC) | |||
Voltmeter accuracy: DC to 1 Hz | Pointer shall track within 5% of peak | |||
2Hz to 19Hz (Accuracy not supported) |
| |||
20 Hz to 1KHz | ±3% F.S. @ 60 Hz (Add ±1% for every additional 100Hz) | |||
Voltmeter frequency response: | DC to 1 KHz | |||
Power requirements: | Power requirements: (2) 9V (NEDA 1604A) batteries | |||
Physical: | 7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic,fusedinput | |||
Environmental: | 27°C ±2° C, 70% non condensing relative humidity. Outside thisrangederate by 10% per °C | |||
Maximum operating range: | 0° to 40° C |
![]() | |
![]() |
您感兴趣的产品PRODUCTS YOU ARE INTERESTED IN
包装印刷网 设计制作,未经允许翻录必究 .
请输入账号
请输入密码
请输验证码
请输入你感兴趣的产品
请简单描述您的需求
请选择省份