上海颐品自动化科技有限公司

Hawke,CMP,CCG,Peppers防爆格兰,电缆接头,电气套管,接线盒等

包装印刷产业网收藏该商铺

您所在位置:
上海颐品自动化科技有限公司>>EPIN电缆接头系列>> Peppers接管式防爆密封接头(Peppers A*LCF type glands)
 QQ交谈
产品展示

Peppers接管式防爆密封接头(Peppers A*LCF type glands)

  • 公司名称:
  • 更新时间:
  • 所 在 地:
  • 生产地址:
  • 浏览次数:
  • 上海颐品自动化科技有限公司
  • 2017-12-04 21:58:14
  • 上海
  • 上海颐品自动化,热线:13818772521
  • 1441

我要询价

【简单介绍】

EPIN英国Peppers防爆格兰,英国Peppers防爆变径接头,英国Peppers防爆堵头,英国Peppers防爆呼吸阀,英国Peppers防爆密封接头,英国Peppers防爆螺纹适配接头,上海颐品自动化,技术:

【详细说明】

英国Peppers防爆格兰系列Peppers cable Gland

上海颐品自动化,:

Including type No’s:
A2LCFBF
 3 CMS 
    A 
“A*LCF” type glands, certified Flameproof Ex d, Increased Safety Ex e & Restricted Breathing Ex nR are suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. They provide a controlled pull resistant environmental displacement seal on the cable outer sheath, minimising damage to cables that exhibit “cold flow” characteristics. The gland maintains IP66 & IP68 to 25 metres and is deluge proof without the use of an additional seal or deluge boot. It is supplied with an IP O-ring seal as standard on metric entry threads. The gland features a female conduit connection thread as standard with an option for a male connection thread.
 
COMPLIANCE STANDARDEN 60079-0, EN 60079-1, EN 60079-7,
EN 60079-15, EN 61241-0, EN 61241-1
IEC 60079-0, IEC 60079-1, IEC 60079-7,
IEC 61241-0, IEC 61241-1 & IEC 60529
CERTIFICATIONATEX II 2 GD Ex d IIC / Ex e II / Ex tD A21
II 3 GD Ex nR II
IECEx Ex d IIC / Ex e II / Ex tD A21
GOST-R Ex d IICU / Ex e IIU
CSA Ex d IIC / Ex e II Class I Zone 1
Class I Division 2, Groups A, B, C & D
Class II Division 2, Groups E, F & G
Class III, Enclosure Types 3, 4 & 4X
NEPSI Ex d IIC / Ex e II
INMETRO BR - Ex d IIC / Ex e II / Ex nR II / Ex tD A21
ABS 1-1-4/7.7, 4.8-3/1.7, 4-8-3/13 and 4-8-4/27.5
MODU Rules 4-3-3/9
LLOYD’S Enclosure Systems (Part 1B)
RMRS Part XI of Rules for sea-going ships (ed.2008)
CERTIFICATE NO.ATEX SIRA 01ATEX1272X & SIRA 09ATEX1221X IECEx SIR 07.0096X
GOST-R POCC GB.06.BOO853
CSA CSA 1356011
NEPSI GYJ06186X
INMETRO NCC 5879/09 X
ABS 09-LD463991-PDA
LLOYD’S 10/00056
RMRS 09.00784.011
IP RATINGIP66 & IP68 (25 metres - 30 minutes), NEMA 4X & DTS01 1991
APPLICATION
EExd Equipment
A2L**F type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use A2L**F Gland

IIC, IIB, IIA

NO

Any

Zone 1 or 2

YES

IIB, IIA

YES

Any

Zone 2

YES

IIB, IIA

YES

2 litres or less

Zone 1

YES


EExe Equipment

Other Equipment
Gas Group II, Zones 1 and 2Ignitable Dust, Zones 21 and 22
MATERIALSBrass, Stainless Steel or Aluminium
OPTIONSTHREADSISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
SEALSExtended operating temperature -60ºC to +180ºC, halogen free versions:
Brass (A3L**F); 316 Stainless Steel (A3L**SF)
PLATINGZinc (ZP); Nickel (NP)
OPERATING TEMPERATURESStandard Seals -20ºC to +85ºC
Silicone Seals -60ºC to +180ºC
ACCESSORIESLocknut Brass (ACBLN) / Stainless Steel (ACSLN)
Earth tag: Brass (ACBET) / Stainless Steel (ACSET)
IP Washers: Nylon (ACNSW) / Fibre (ACFSW)
Serrated Washers: Stainless Steel (ACSSW)
EXAMPLE PART NUMBERINGSample: A2LCFBF050NPT/NP/20/M20
A: Type of gland featuring controlled displacement sealing
2: Neoprene Seals (2) - Silicone (3)
L: Peppers Lightweight Design
CF: Female Conduit Connection Thread (CF) / Male Thread Option (CM)
B: Brass (B) / Stainless Steel (S) / Aluminium (A)
F: Multiple Certification
050NPT: 1/2”NPT Female Conduit Connection Thread
NP: Nickel Plated (NP) - Zinc Plated (ZP)
20: Gland shell size
M20: M20 x 1.5 Entry Thread
Gland Size
Entry Threads
MetricNPT/BSP
Entry Thread Length
[B]
Max Across Corners
[A]
Gland Seal Range
Cable Outer Sheath [D]
MinMax
Conduit Connector
NPTISO
16M20 x 1.51/2" or 3/4"1628.04.08.41/2" or 3/4"M20 x 1.5
20sM20 x 1.51/2" or 3/4"1628.07.211.71/2" or 3/4"M20 x 1.5
20M20 x 1.51/2" or 3/4"1633.09.414.01/2" or 3/4"M20 x 1.5
25M25 x 1.53/4" or 1"1641.413.520.03/4" or 1"M25 x 1.5
32M32 x 1.51" or 1*1/4"1650.619.526.31" or 1*1/4"M32 x 1.5
40M40 x 1.51*1/4" or 1*1/2"1660.523.032.21*1/4" or 1*1/2"M40 x 1.5
50sM50 x 1.51*1/2" or 2"1671.528.138.21*1/2" or 2"M50 x 1.5
50M50 x 1.52”1671.533.144.12”M50 x 1.5
63sM63 x 1.52" or 2*1/2"1988.039.250.12" or 2*1/2"M63 x 1.5
63M63 x 1.52*1/2"1988.046.756.02*1/2"M63 x 1.5
75sM75 x 1.52*1/2" or 3"1999.052.162.02*1/2" or 3"M75 x 1.5
75M75 x 1.53”1999.058.068.03”M75 x 1.5
80M80 x 23” or 3 1/2”25115.262.272.03” or 3 1/2”M80 x 2
85M85 x 23” or 3 1/2”25115.269.078.03” or 3 1/2”M85 x 2
90M90 x 23 1/2” or 4”25125.774.084.03 1/2” or 4”M90 x 2
100M200 x 23 1/2” or 4"25125.782.090.03 1/2” or 4"M200 x 2
All Dimensions are in Millimetres
NOTES:
  • Gland size does not necessarily equate to the entry thread size. Gland size 16 is also available with an M16 x 1.5 entry thread.
  • The IP O-ring seal is only available on metric entry threads. IP washers can be supplied for tapered entry threads.
  • Please ensure that the IP O-ring is not used in conjunction with a flat IP washer.
  • Dimensions (A) & (B) may differ for glands with non metric entry threads. Please refer to our “Thread Reference Tables” for specific dimensions.
  • Where glands are fitted into non-metallic Ex e enclosures they must be included within the earth circuit of the system.
  • The user should seek expert advice if intending to combine flammable and combustible dust in one environment/installation.
  • Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system
  • The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/ installation
  • Assembly instructions must be read prior to installation and adhered to in full.
  • Peppers supplies cable glands with parallel entry threads that conform to the flameproof threaded joint requirements of IEC/EN 60079-1 and other equivalent standards. They usually incorporate a thread run out according to the available machining techniques and will not have a full form thread for the entire length. Peppers will not be held responsible for clients’ installations where this has not been taken into account.
  • To maintain the specified IP rating, clearance holes must be in accordance with EN 50262 Table 1 and the entry device should be suitably secured.

 

 

中国区分销商:
上海颐品自动化科技有限公司

Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

因为专业,所以放心!

    
留言框
感兴趣的产品: *
留言内容:
您的姓名: *
您的单位:
联系电话: *
微信:
常用邮箱:
详细地址:
省份: *
验证码: * =   请输入计算结果(填写阿拉伯数字),如:三加四=7
是否接受其他厂商报价: *
      

相关产品

产品搜索

请输入产品关键字:

联系方式
地址:上海浦东新区大麦湾工业区
邮编:200138
联系人:张凯文
留言:在线留言
商铺:https://www.ppzhan.com/st29030/
| 商铺首页 | 公司档案 | 产品展示 |公司动态 | 询价留言 | 联系我们 | 会员管理 |
包装印刷产业网 设计制作,未经允许翻录必究.Copyright(C) https://www.ppzhan.com, All rights reserved.
以上信息由企业自行提供,信息内容的真实性、准确性和合法性由相关企业负责,包装印刷产业网对此不承担任何保证责任。
温馨提示:为规避购买风险,建议您在购买产品前务必确认供应商资质及产品质量。
二维码

扫一扫访问手机站